Hydrodam large pipe flow measurements . Our team received the project order locally
through a successful contractor and carried out measurements on a daily rate.

Portable Flow surveys on an underground water pipe with a thick cement liner. No verifiable flow readings had been obtained before our visit.
Measuring Fluids with large amount of suspended solids in a waste water treatment plant.
This measurement was only possible using Doppler techniques. The possibilities of installing fixed Doppler meters (EESIFLO 3000 series) was explored by using the EESIFLO 10P microprocessor based clamp on hand held Doppler meter.
Installation of clamp on flowmeters at a water treatment plant in the Gulf
Bi-directional flows on a small copper pipe undergoing tests using an EESIFLO clamp on panel mount device. Test runs were conducted before installing the meter in the panel along with other instrumentation
Charging /Testing EESIFLO EASZ-11FP before shipment to a Gulf client
Send mail to sales@eurogulfco.com for additional information. Copyright © 2003 EURO GULF GROUP CO.